Page 141 - water-controls-for-public-commercial-places
P. 141

Point-of-use filters /


               MANAGING WATERBORNE                        BIOFIL FILTERS PERFORMANCE
               HEALTH RISKS


               Water, essential for hygiene, can also be a source    Hollow fibre filter
               of infection if its quality is not controlled.   Each BIOFIL filter incorporates a hollow fibre
               The proliferation of bacteria (Legionella,   membrane with a water filtration threshold
               Pseudomonas aeruginosa, etc.) in the water supply    of 0.1 micron absolute-rated. They deliver water
               or in mixers and taps may cause serious infections,   free from microorganisms (bacteria, protozoa, fungi,
               especially for vulnerable people.         particles in water systems...) without changing    Bacteriologically controlled water
               Water systems in all buildings open to the public should   its chemical composition.
               be monitored for Legionella i.e. swimming pools,   They provide total protection against waterborne
               leisure centres, hotels and holiday accommodation,   infection.
               campsites, medical social care and social care
               establishments, spaces for disabled people, prisons, etc.  Larger filtration area than flat membrane
                                                         The filtration area is substantially
               This applies in all circumstances where the Health    larger in BIOFIL filters with hollow fibre    Filter   Hollow
                                                                                                                  fibres
                                                                                                     unit
               and Safety at Work Act 1974 - which imposes    membranes than it is in flat membranes.
               the monitoring of the bacteriological quality of water   This large filtration area allows a larger volume   Resin     SHOWERS
               in sanitary installations - applies.      of water to be filtered. Consequently the storage
               The prevention of health risks associated with   capacity for bacteria and impurities trapped inside
               pathogenic bacteria in water systems should be    the filter is much greater.
               a constant concern for public buildings.                                             Section of the BIOFIL tap filter
               The BIOFIL range of point-of-use filters is a   Reduced risk of premature clogging
               preventative or curative solution to secure the water   Articles in suspension stay on the surface of the
               quality at the point-of-use and protect the health of   hollow fibre membrane which delays clogging.
               the user.                                 The large capacity of the storage area means that the
                                                         membrane's lifespan is longer.
                                                         Extremely compact filters
               AREAS OF USE                              Unlike other point-of-use filters on the market, BIOFIL
                                                         filters are smaller due to the compact nature of
               Anti-Legionella and all-germ filters       the fibre. They are suitable for most water controls
               Non-sterile BIOFIL filters are CE marked class I   on the market.                     Tilted to optimise the position
               Medical Devices. Sterile BIOFIL filters are CE marked                                 of the tap filter
               class Is Medical Devices.
               In public and commercial places, they protect users   MANUFACTURING PROCESS
               from the risk of Legionella and provide immediate
               compliance with standard regulations. They are   IS MONITORED CONSTANTLY
               suitable for all types of buildings open to the public
               for the following usage: body hygiene, hand-washing   100% quality controlled
               and balneotherapy.
                                                         The fibre quality and porosity of the finished product
               BIOFIL filters can be installed on the compromised   are continuously monitored during the manufacturing
               point-of-use (basin or shower). They filter water   process for 100% of the fibres.
               directly at the point-of-use ensuring the water is free
               from bacteria.
                                                          COMPONENT DISPOSAL                        CE marked class I Medical
                                                                                                    Devices for non-sterile filters
                                                          STRATEGY                                  CE marked class Is Medical
                                                                                                    Devices for sterile filters
               CHEMICAL FREE                             BIOFIL filters are classified as household waste.
                                                         The outer packaging is made from recycled
                                                         cardboard which is also fully recyclable.
               No chemicals are used in the making of our filters.


                THE INSTANT BIOFIL SOLUTION

                Mixer or tap can be used immediately after
                installation of the filter.
















                                                                                                           Showers  139