Page 52 - water-controls-for-public-commercial-places
P. 52

/ Time flow basin controls


                                      TECHNICAL SOLUTIONS                       SPECIFICALLY DESIGNED FOR
                                      FOR ALL CONSTRAINTS                       COMMERCIAL ENVIRONMENTS

                                      Public and commercial buildings have different   Resistant to intensive use and vandalism
                                      requirements depending on the place of installation   DELABIE’s time flow mixers and taps are specifically
                                      and type of user. DELABIE has developed specific   designed to withstand intensive use as well as
                                      products to respond to a variety of challenges   voluntary and involuntary vandalism.
                                      (improving comfort, avoiding waste, user safety, etc.).  The mixer and tap bodies are made from brass,
                                                                                fitted with shock-resistant mechanisms.
                 Soft technology:     Soft technology: soft-touch operation     The reinforced fixings will stand up to intensive use.
                 soft-touch operation
                                      DELABIE has developed time flow mixers and taps    Streamlined designs prevent unwanted removal.
                                      with soft-touch operation. Soft technology allows    For areas that require tamperproof installations,
                                      all users (children, the elderly or people with reduced   there are recessed and cross wall versions which have
                                      mobility) to use the mixers and taps with no effort   mechanisms that cannot be accessed by the user.
                                      required.
                                      TEMPOSOFT 2, TEMPOMIX and TEMPOMIX 3      Superior endurance
                                      models require half the effort to operate compared    The time flow mechanisms in DELABIE mixers and taps
                                      to conventional taps/mixers.              are hard-wearing. The hydraulic timing system
                                                                                with a calibrated groove is self-cleaning, which extends
                                      AB anti-blocking system: waste prevention  its lifespan to over 500,000 operations.
                                      To avoid abuse and waste, TEMPOSTOP (models 1 to 4),   There is no metal-metal or metal-plastic friction,
                                      TEMPOMIX 2 and TEMPOMIX 3 models can be fitted   ensuring reliable and durable timing.
                 AB anti-blocking system
                                      with an AB anti-blocking system.          DELABIE’s mixers and taps perform to the highest
                                      This prevents the valve from being blocked in the open   standards. Each model is subjected to endurance tests
                                      position. Water will not flow unless the push-button    under extreme conditions in endurance laboratories.
                                      is released.
                                                                                Easy to install
                                      Temperature selection                     For a quick activation and comfort with no splashing
                                      Mixer versions (MIX) of DELABIE’s time flow taps   all DELABIE's time flow mixers and taps are pre-set
                                      are available. They offer the user additional comfort   at 3 lpm at 3 bar. They can, however, be adjusted
                                      by allowing them to choose the water temperature.   from 1.4 (see environmental labels) to 6 lpm.
                                      Temperature adjustment is done via the single control   They are supplied with a pre-set maximum
                                      (TEMPOMIX and TEMPOMIX 3) or using the side lever   temperature limiter to save time during installation,
                 Vandal-resistant     (TEMPOMIX 2 and TEMPOSOFT MIX 2 and       and can be adjusted by the installer.
                                      TEMPOSTOP MIX 4).
                                                                                Minimal servicing
                                      Anti-scalding safety                      Flow straighteners and mechanisms are made from
                                                                                                            ®
                                      DELABIE's time flow mixers are supplied with    scale-resistant materials (Hostaform ).
                                YEAR  a pre-set maximum temperature limiter that can be   The self-cleaning mechanisms are protected by filters.
                                      adjusted during installation. The user cannot increase
                                      the temperature above the maximum set temperature,   Simple to maintain
                                      reducing any risk of scalding.            The spare parts are standardised to ensure quick
                     WARRANTY
                                                                                and easy replacement by maintenance staff.
                                      Technical characteristics                 The whole of the system is integrated within
                                                                                an interchangeable cartridge without removing
                                      Operating pressure  1 - 5 bar, 3 bar recommended  the tap. For the mixer versions, non-return valves
                                      Pressure differential    ∆P < 1 bar       are integrated into the flexibles.
                                      HW / CW
                                YEARS  Temperature limiter*    Adjustable       30-year warranty against any manufacturing defects.
                                                                                50 years repairability.
                                      HW supply
                                                               55°C max
                   REPAIRABILITY      Adjustable flow rate     1.4 lpm - 6 lpm
                                      Time flow                 7 seconds
                                                          TEMPOSOFT 2, TEMPOMIX,
                                      Soft-touch technology
                                                              TEMPOMIX 3
                                                         TEMPOSTOP, TEMPOSTOP 2,
                                      Anti-blocking system   TEMPOSTOP 3, TEMPOSTOP 4,
                                                          TEMPOMIX 2, TEMPOMIX 3